Skip to main content

วิธีการคำนวณ Column Buckling

learn.whatIsHeading

Euler column buckling predicts critical load at which slender columns fail by instability rather than material crushing. It's essential for structural safety.

สูตร

Calculate: P_cr = π²EI/(KL)² where K is effective length factor
KL
KL value — Variable used in the calculation
K
K value — Variable used in the calculation

คำแนะนำทีละขั้นตอน

  1. 1Calculate: P_cr = π²EI/(KL)² where K is effective length factor
  2. 2Compare to axial compression strength
  3. 3Results determine column design adequacy

ตัวอย่างที่มีคำตอบ

อินพุต
E = 200 GPa, I = 2×10⁹ mm⁴, L = 4 m, K = 1 (pinned)
ผลลัพธ์
P_cr ≈ 2.47 MN (critical load)
Higher leads to buckling

ข้อผิดพลาดที่ควรหลีกเลี่ยง

  • Using unsupported length instead of effective length
  • Neglecting lateral bracing effects on K

คำถามที่พบบ่อย

Why do long columns fail at lower loads?

Buckling instability dominates; longer unsupported length reduces critical load dramatically (proportional to 1/L²).

What is effective length factor K?

K accounts for end conditions: K=0.5 (fixed-fixed), K=1 (pinned-pinned), K=2 (cantilever).

พร้อมที่จะคำนวณแล้วหรือยัง? ลองใช้เครื่องคิดเลข Column Buckling ฟรี

ลองด้วยตัวคุณเอง→

การตั้งค่า