Determines inverter capacity to handle peak loads from solar or battery systems. Prevents inadequate power and equipment damage.

Hướng dẫn từng bước

  1. 1Sum peak simultaneous power consumption (watts)
  2. 2Account for inrush current (motors 3-5× running)
  3. 3Add 25-50% capacity headroom for growth
  4. 4Select inverter rated 120-150% of peak load

Ví dụ có lời giải

đầu vào
2000W peak load
Kết quả
3000W inverter

Lỗi thường gặp cần tránh

  • Using average power instead of peak power
  • Not accounting for motor inrush current

Câu hỏi thường gặp

What happens if inverter is undersized?

Insufficient power for peak loads, brownouts, equipment damage, and automatic shutoff.

What if inverter is oversized?

Wastes money; minor efficiency loss; better to slightly oversize than undersized.